6
InstallatIon & operatIon
Battery Types: SCC-30AB’s standard battery charging programs are suitable for a wide
range of Lead-Acid battery types. These standard programs are select by DIP Switch
2~4. There is also one program for Ni-Cd battery (see Table 6.1).
Standard Battery Charging Programs
SCC-30AB provides 8 standard battery charging algorithms (programs) that are
selected with DIP Switches 2, 3, 4. These standard algorithms are suitable for Lead-Acid
batteries ranging from sealed (Gel, AGM, maintenance free) to ooded to L-16 cells
and Ni-Cd etc.
Table 6.1 below summarizes the major parameters of the standard charging
algorithms. Note that all the voltages are for 12V systems. For 24V system, multiply
the voltages by 2.
Consult the battery manufacturer / battery specications & select the appropriate Algorithm.
The unit is preset for Battery Type 1 (OFF-OFF-OFF) for a sealed / VRLA battery.
For a generic non-sealed / vented / ooded / well cell Lead Acid battery, choose Battery Type 4.
NOTE:
1. All Voltage values are at battery temperature of 25ºC (77ºF).
2. All the voltages given in the Table are for 12V Battery System.
For 24V Battery Systems multiply the voltage values by 2.
A B C D E F
DIP
Switches
(2-3-4)
Battery
Type
Absorption
Voltage
Float
Voltage
Equalize
Voltage
Equalize
Time
(hours)
Equalize
Interval
(days)
OFF-OFF-OFF
(Factory Preset)
1 – Sealed 14.0 13.4 None - -
OFF-OFF-ON 2 – Sealed 14.1 13.4 14.2 1 28
OFF-ON-OFF 3 - Sealed 14.3 13.4 14.4 2 28
OFF-ON-ON 4 - Flooded 14.4 13.4 15.1 3 28
ON-OFF-OFF 5 - Flooded 14.6 13.4 15.3 3 28
ON-OFF-ON 6 - Flooded 14.8 13.4 15.3 3 28
ON-ON-OFF 7 - L-16 15.0 13.4 15.3 3 14
ON-ON-ON
8 - Ni-Cd 16.0 14.5 None - -
Table 6.1. Standard Battery Charging Programs
A. Battery Type These are generic Lead-Acid – wet cell (Lead Antimony, Lead Calcium),
sealed AGM, sealed Gel Cell and Ni-Cd battery types.
B. Absorption/Voltage This is the Absorption Voltage Regulation Set Point. Note: This voltage
will be displayed as “Bulk” on Screen 5 of LCD Display (Fig. 5.3).